All Categories
EN EN

ASVG 500V SERIES

500V Advanced Static Var Generator (ASVG)

\n
Reactive Power Compensation, Harmonic control, Three-phase unbalance control
\n
Advanced Static Var Generator (ASVG) is a new type of dynamic reactive power compensation product, which is representative of the latest technology application in the field of reactive power compensation. By adjusting the phase and amplitude of the output voltage on the AC side of the inverter, or directly controlling the current on the AC side of the inverter
\n
Amplitude and phase, quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated. Enhanced static var generators (ASVGs) are high-performance, compact, flexible, modular, and cost-effective to provide immediate and efficient responses to power quality problems in high and low voltage power systems. They improve power quality, extend equipment life and reduce energy losses.
\n
ASVG Working Principle:
\n
External CT detects the load current in real time, internal DSP calculates and abstracts the reactive power and harmonic content of the load current, then send the PWM signal to internal IGBT, adjusts the phase and amplitude of the output voltage on the AC side of the inverter or directly control the phase and amplitude of the current on the AC side of the inverter. quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated.
\n
\"ASVG1.png\"
\n
ASVG Technical Specifications
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
TypeSeries 220VSeries 380V Series 500V Series 690V 
Nominal VoltageAC220V±20%AC400V(-20%~+15%)AC500V±20%AC690V(-20%~+15%)
Rated Frequency50Hz/60Hz45Hz~63Hz
Rated Compensation Capacity5kvar10kvar, 15kvar, 35kvar, 50kvar, 75kvar, 100kvar90kvar120kvar
Grid StructureL/N3P3W/3P4W
Full Response Time<40ms
Numbers in ParallelNo limitation
Reactive Power Compensation Rate>99%>95%
Machine Efficiency>97%
Switching Frequency32kHz16kHz12.8kHz
Feature Selection Deal with harmonics/Deal with harmonics and reactive power
Deal with harmonics/Deal with harmonics and reactive power/Deal with harmonics and three-phase unbalance /Three options
Communication Methods Two-channel RS485 communication interface 
(support GPRS/WIFI wireless communication)
Protection FunctionOverload, Software/Hardware Over-current, Grid Over/Under Voltage, Voltage Unbalance, Power Supply Fault, Over-temperature, Frequency Abnormality, Short Circuit Protection, etc.
Altitude without Derating<2000m
Temperature-10℃ ~ 50℃(capacity degrade above 40°C)
Humidity≤90%,Minimum Monthly Temperature of 25°C with No Surface Condensation
Pollution LevelBelow level Ⅲ
Noise<60dB<65dB
InstallationRack/Wall-mountedRack-mounted
Inlet WayBack entry (for Rack) / Top entry (for Wall-mounted)
Protection GradeIP20
\n
\n
\n
\n
\"ASVG2.png\"
\n
\n
\n
SVG Product Appearance
\n
1、Rack-mounted
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (kvar)System Voltage (V)Size (W1*D1*H1)Cooling Mode
ASVG-0.22-5k/2L-R5220220*330*160Forced Air Cooling
ASVG-0.4-10k/4L-R10400460*490*89Forced Air Cooling
ASVG-0.4-15k/4L-R15400460*490*89Forced Air Cooling
ASVG-0.4-35k/4L-R35400460*490*89Forced Air Cooling
ASVG-0.4-50k/4L-R50400500*510*190Forced Air Cooling
ASVG-0.4-75k/4L-R75400500*550*240Forced Air Cooling
ASVG-0.4-100k/4L-R100400500*550*240Forced Air Cooling
ASVG-0.5-90k/4L-R90500495*675*275Forced Air Cooling
ASVG-0.69-120k/4L-R120690495*675*275Forced Air Cooling
\n
\n
\n
\"ASVG3.png\"
\n
2、Wall-mounted
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (kvar)System Voltage (V)Size (W1*D1*H1)Cooling Mode
ASVG-0.22-5k/2L-R5220220*330*160Forced Air Cooling
ASVG-0.4-10k/4L-R10400460*490*89Forced Air Cooling
ASVG-0.4-15k/4L-R15400460*490*89Forced Air Cooling
ASVG-0.4-35k/4L-R35400460*490*89Forced Air Cooling
ASVG-0.4-50k/4L-R50400500*510*190Forced Air Cooling
ASVG-0.4-75k/4L-R75400500*550*240Forced Air Cooling
ASVG-0.4-100k/4L-R100400500*550*240Forced Air Cooling
ASVG-0.5-90k/4L-R90500495*675*275Forced Air Cooling
ASVG-0.69-120k/4L-R120690495*675*275Forced Air Cooling
\n
\n
\"ASVG4.jpg\"
\n
3、Full Cabinet Load
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (kvar)System Voltage (V)Size (W3*D3*H3)Cooling Mode
ASVG-0.4-200k/4L-C2004001000*1000*2200Forced Air Cooling
ASVG-0.4-250k/4L-C2504001000*1000*2200Forced Air Cooling
ASVG-0.4-300k/4L-C3004001000*1000*2200Forced Air Cooling
ASVG-0.4-400k-4L-C4004001000*1000*2200Forced Air Cooling
ASVG-0.5-270k/4L-C2705001000*1000*2200Forced Air Cooling
ASVG-0.69-360k/4L-C3606901000*1000*2200Forced Air Cooling
\n
\n
\n
\"ASVG5.png\"
\n
\n
","info":"Advanced Static Var Generator (ASVG)\nReactive Power Compensation, Harmonic control, Three-phase unbalance control\nAdvanced Static Var Generator (ASVG) is a new type of dynamic reactive power compensation product, which is representative of the latest technology application in the field of reactive power compensation. By adjusting the phase and amplitude of the output voltage on the AC side of the inverter, or directly controlling the current on the AC side of the inverter\nAmplitude and phase, quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated. Enhanced static var generators (ASVGs) are high-performance, compact, flexible, modular, and cost-effective to provide immediate and efficient responses to power quality problems in high and low voltage power systems. They improve power quality, extend equipment life and reduce energy losses.\nASVG Working Principle:\nExternal CT detects the load current in real time, internal DSP calculates and abstracts the reactive power and harmonic content of the load current, then send the PWM signal to internal IGBT, adjusts the phase and amplitude of the output voltage on the AC side of the inverter or directly control the phase and amplitude of the current on the AC side of the inverter. quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated.\n\nASVG Technical Specifications\n\n \n\n\nType\nSeries 220V\nSeries 380V \nSeries 500V \nSeries 690V \n\n\nNominal Voltage\nAC220V±20%\nAC400V(-20%~+15%)\nAC500V±20%\nAC690V(-20%~+15%)\n\n\nRated Frequency\n50Hz/60Hz(45Hz~63Hz)\n\n\nRated Compensation Capacity\n5kvar\n10kvar, 15kvar, 35kvar, 50kvar, 75kvar, 100kvar\n90kvar\n120kvar\n\n\nGrid Structure\nL/N\n3P3W/3P4W\n\n\nFull Response Time\n<40ms\n\n\nNumbers in Parallel\nNo limitation\n\n\nReactive Power Compensation Rate\n>99%\n>95%\n\n\nMachine Efficiency\n>97%\n\n\nSwitching Frequency\n32kHz\n16kHz\n12.8kHz\n\n\nFeature Selection\nDeal with harmonics/Deal with harmonics and reactive powerDeal with harmonics/Deal with harmonics and reactive power/Deal with harmonics and three-phase unbalance /Three options\n\n\nCommunication Methods\nTwo-channel RS485 communication interface (support GPRS/WIFI wireless communication)\n\n\n\n\nProtection Function\nOverload, Software/Hardware Over-current, Grid Over/Under Voltage, Voltage Unbalance, Power Supply Fault, Over-temperature, Frequency Abnormality, Short Circuit Protection, etc.\n\n\nAltitude without Derating\n<2000m\n\n\nTemperature\n-10℃ ~ 50℃(capacity degrade above 40°C)\n\n\nHumidity\n≤90%,Minimum Monthly Temperature of 25°C with No Surface Condensation\n\n\nPollution Level\nBelow level Ⅲ\n\n\nNoise\n<60dB\n<65dB\n\n\nInstallation\nRack/Wall-mounted\nRack-mounted\n\n\nInlet Way\nBack entry (for Rack) / Top entry (for Wall-mounted)\n\n\nProtection Grade\nIP20\n\n\n\n\n\n\n\n\n\nSVG Product Appearance\n1、Rack-mounted\n\n \n\n\nModel\nCompensation Capacity (kvar)\nSystem Voltage (V)\nSize (W1*D1*H1)\nCooling Mode\n\n\n\n\nASVG-0.22-5k/2L-R\n5\n220\n220*330*160\nForced Air Cooling\n\n\nASVG-0.4-10k/4L-R\n10\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-15k/4L-R\n15\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-35k/4L-R\n35\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-50k/4L-R\n50\n400\n500*510*190\nForced Air Cooling\n\n\nASVG-0.4-75k/4L-R\n75\n400\n500*550*240\nForced Air Cooling\n\n\nASVG-0.4-100k/4L-R\n100\n400\n500*550*240\nForced Air Cooling\n\n\nASVG-0.5-90k/4L-R\n90\n500\n495*675*275\nForced Air Cooling\n\n\nASVG-0.69-120k/4L-R\n120\n690\n495*675*275\nForced Air Cooling\n\n\n\n\n\n\n2、Wall-mounted\n\n \n\n\nModel\nCompensation Capacity (kvar)\nSystem Voltage (V)\nSize (W1*D1*H1)\nCooling Mode\n\n\n\n\nASVG-0.22-5k/2L-R\n5\n220\n220*330*160\nForced Air Cooling\n\n\nASVG-0.4-10k/4L-R\n10\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-15k/4L-R\n15\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-35k/4L-R\n35\n400\n460*490*89\nForced Air Cooling\n\n\nASVG-0.4-50k/4L-R\n50\n400\n500*510*190\nForced Air Cooling\n\n\nASVG-0.4-75k/4L-R\n75\n400\n500*550*240\nForced Air Cooling\n\n\nASVG-0.4-100k/4L-R\n100\n400\n500*550*240\nForced Air Cooling\n\n\nASVG-0.5-90k/4L-R\n90\n500\n495*675*275\nForced Air Cooling\n\n\nASVG-0.69-120k/4L-R\n120\n690\n495*675*275\nForced Air Cooling\n\n\n\n\n\n3、Full Cabinet Load\n\n \n\n\nModel\nCompensation Capacity (kvar)\nSystem Voltage (V)\nSize (W3*D3*H3)\nCooling Mode\n\n\n\nASVG-0.4-200k/4L-C\n200\n400\n1000*1000*2200\nForced Air Cooling\n\n\nASVG-0.4-250k/4L-C\n250\n400\n1000*1000*2200\nForced Air Cooling\n\n\nASVG-0.4-300k/4L-C\n300\n400\n1000*1000*2200\nForced Air Cooling\n\n\nASVG-0.4-400k-4L-C\n400\n400\n1000*1000*2200\nForced Air Cooling\n\n\nASVG-0.5-270k/4L-C\n270\n500\n1000*1000*2200\nForced Air Cooling\n\n\nASVG-0.69-360k/4L-C\n360\n690\n1000*1000*2200\nForced Air Cooling\n\n\n\n\n\n\n\n","desc":"Advanced Static Var Generator (ASVG)\nReactive Power Compensation, Harmonic control, Three-phase unbalance control\nAdvanced Static Var Generator (ASVG) is a new type of dynamic reactive power compensation product, which is representative of the latest...","date":"2024-10-23","visits":0,"color":"","category":"ASVG 500V Series","sname":"","slink":"https://www.ampersure.com/90kvar242","tag":"","down":"
","downname":"","downurl":"","prev":null,"next":null,"count":1,"specs":[],"skus":[],"product_summary":"","product_image_video":"","brand_manufacturer":"","product_code_spu":"","extension_title":"","extension_content":[{"extension_title":"","extension_content":""}],"product_price":"0.00","need_show_price":0}
  • Overview
  • Related Products
Advanced Static Var Generator (ASVG)
Reactive Power Compensation, Harmonic control, Three-phase unbalance control
Advanced Static Var Generator (ASVG) is a new type of dynamic reactive power compensation product, which is representative of the latest technology application in the field of reactive power compensation. By adjusting the phase and amplitude of the output voltage on the AC side of the inverter, or directly controlling the current on the AC side of the inverter
Amplitude and phase, quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated. Enhanced static var generators (ASVGs) are high-performance, compact, flexible, modular, and cost-effective to provide immediate and efficient responses to power quality problems in high and low voltage power systems. They improve power quality, extend equipment life and reduce energy losses.
ASVG Working Principle:
External CT detects the load current in real time, internal DSP calculates and abstracts the reactive power and harmonic content of the load current, then send the PWM signal to internal IGBT, adjusts the phase and amplitude of the output voltage on the AC side of the inverter or directly control the phase and amplitude of the current on the AC side of the inverter. quickly absorb or emit the required reactive power and harmonic current, and realize the purpose of fast dynamic adjustment of reactive power and harmonic compensation. Not only can the reactive current of the load can be tracked and compensated, but also the harmonic current can also be tracked and compensated.
ASVG1.png
ASVG Technical Specifications
Type Series 220V Series 380V  Series 500V  Series 690V 
Nominal Voltage AC220V±20% AC400V(-20%~+15%) AC500V±20% AC690V(-20%~+15%)
Rated Frequency 50Hz/60Hz45Hz~63Hz
Rated Compensation Capacity 5kvar 10kvar, 15kvar, 35kvar, 50kvar, 75kvar, 100kvar 90kvar 120kvar
Grid Structure L/N 3P3W/3P4W
Full Response Time <40ms
Numbers in Parallel No limitation
Reactive Power Compensation Rate >99% >95%
Machine Efficiency >97%
Switching Frequency 32kHz 16kHz 12.8kHz
Feature Selection Deal with harmonics/Deal with harmonics and reactive power
Deal with harmonics/Deal with harmonics and reactive power/Deal with harmonics and three-phase unbalance /Three options
Communication Methods Two-channel RS485 communication interface 
(support GPRS/WIFI wireless communication)
Protection Function Overload, Software/Hardware Over-current, Grid Over/Under Voltage, Voltage Unbalance, Power Supply Fault, Over-temperature, Frequency Abnormality, Short Circuit Protection, etc.
Altitude without Derating <2000m
Temperature -10℃ ~ 50℃(capacity degrade above 40°C)
Humidity ≤90%,Minimum Monthly Temperature of 25°C with No Surface Condensation
Pollution Level Below level Ⅲ
Noise <60dB <65dB
Installation Rack/Wall-mounted Rack-mounted
Inlet Way Back entry (for Rack) / Top entry (for Wall-mounted)
Protection Grade IP20
ASVG2.png
SVG Product Appearance
1、Rack-mounted
Model Compensation Capacity (kvar) System Voltage (V) Size (W1*D1*H1) Cooling Mode
ASVG-0.22-5k/2L-R 5 220 220*330*160 Forced Air Cooling
ASVG-0.4-10k/4L-R 10 400 460*490*89 Forced Air Cooling
ASVG-0.4-15k/4L-R 15 400 460*490*89 Forced Air Cooling
ASVG-0.4-35k/4L-R 35 400 460*490*89 Forced Air Cooling
ASVG-0.4-50k/4L-R 50 400 500*510*190 Forced Air Cooling
ASVG-0.4-75k/4L-R 75 400 500*550*240 Forced Air Cooling
ASVG-0.4-100k/4L-R 100 400 500*550*240 Forced Air Cooling
ASVG-0.5-90k/4L-R 90 500 495*675*275 Forced Air Cooling
ASVG-0.69-120k/4L-R 120 690 495*675*275 Forced Air Cooling
ASVG3.png
2、Wall-mounted
Model Compensation Capacity (kvar) System Voltage (V) Size (W1*D1*H1) Cooling Mode
ASVG-0.22-5k/2L-R 5 220 220*330*160 Forced Air Cooling
ASVG-0.4-10k/4L-R 10 400 460*490*89 Forced Air Cooling
ASVG-0.4-15k/4L-R 15 400 460*490*89 Forced Air Cooling
ASVG-0.4-35k/4L-R 35 400 460*490*89 Forced Air Cooling
ASVG-0.4-50k/4L-R 50 400 500*510*190 Forced Air Cooling
ASVG-0.4-75k/4L-R 75 400 500*550*240 Forced Air Cooling
ASVG-0.4-100k/4L-R 100 400 500*550*240 Forced Air Cooling
ASVG-0.5-90k/4L-R 90 500 495*675*275 Forced Air Cooling
ASVG-0.69-120k/4L-R 120 690 495*675*275 Forced Air Cooling
ASVG4.jpg
3、Full Cabinet Load
Model Compensation Capacity (kvar) System Voltage (V) Size (W3*D3*H3) Cooling Mode
ASVG-0.4-200k/4L-C 200 400 1000*1000*2200 Forced Air Cooling
ASVG-0.4-250k/4L-C 250 400 1000*1000*2200 Forced Air Cooling
ASVG-0.4-300k/4L-C 300 400 1000*1000*2200 Forced Air Cooling
ASVG-0.4-400k-4L-C 400 400 1000*1000*2200 Forced Air Cooling
ASVG-0.5-270k/4L-C 270 500 1000*1000*2200 Forced Air Cooling
ASVG-0.69-360k/4L-C 360 690 1000*1000*2200 Forced Air Cooling
ASVG5.png

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000