400V Advanced Static Var Generator (ASVG)
- Rated Frequency: 45Hz-63Hz
- Compensating Current: 10kvar, 15kvar, 35kvar, 50kvar, 75kvar, 100kvar
- Reactive Power Compensation Rate : >95%
- Machine Efficiency : >97%
- Installation: Rack-mounted, Wall-mounted
- Overview
- Specification
- Appearance
- Related Products
Product Overview
Advanced Static Var Generator (ASVG)is a novel current-type power quality management device.It adjusts the phase and amplitude of the output voltage on the inverter's AC side by real-time monitoring of the load current.This allows it to provide precise,simultaneous compensation for system reactive power,harmonics,and three-phase unbalanced currents.The ASVG is characterized by its strong comprehensive compensation capabilities,fast response time,and high cost-effectiveness,making it a better solution in the field of power quality management.
ASVG 400V Technical Specification
ASVG 400V Series |
||||
Altitude |
<2000m,Usage should be de-rated according to the international standard IEC3859-2 for altitudes above 2000 meters. |
|||
Ambient Temperature |
-10°C to+50°C (derated above 40℃) |
|||
Relative Humidity |
≤90%,monthly minimum temperature 25℃,nocondensation on the surface |
|||
Pollution Level |
Below Level III |
|||
Operating Voltage |
AC380V (-20%~+20%) |
|||
Operating Frequency |
50Hz/60Hz(45Hz~63Hz) |
|||
Rated Compensation Capacity |
10kvar,15kvar,35kvar, 50kvar,75kvar,100kvar |
|||
Power Grid Structure |
Three-phase three-wire,Three-phase four-wire |
|||
Numbersin Parallel |
Unlimited |
|||
System Efficiency |
≥97% |
|||
Switching Frequency |
16kHz |
|||
Function Selection |
Reactive Power. Harmonics, ReactivePower+Harmonics, Harmonics+Reactive Power, Harmonics+Unbalance, Reactive Power+Unbalance, Harmonics+Unbalance+Reactive Power ReactivePower+Unbalance+Harmonics Self-Aging Reactive Power, |
|||
Full Response Time |
<40ms |
|||
Noise |
≤60dB |
|||
Communication |
2*RS485 Communication Ports(Supports GPRS/WIFI) |
|||
Protection |
Overload, software/hardware over current, power grid over voltage/under voltage, power failure, over-temperature, frequency abnormality, short circuit protection |
|||
Installation |
Rack-Mounted,Wall-Mounted |
|||
Entry Line Method |
Rear Inlet(rack-mounted), Top Inlet(wall-mounted) |
|||
Protection Level |
IP20 |
ASVG 400V Product Appearance
Module model |
||||
Models |
Compensation Capacity(kvar) |
System Voltage(V) |
Dimensions Width*Depth*Height (mm) |
Cooling System |
AMS ASVG-0.4-10k/4L-R(W) |
10 |
400 |
460*490*89 |
ForcedAir Cooling |
AMS ASVG-0.4-15k/4L-R(W) |
15 |
400 |
460*490*89 |
Forced Air Cooling |
AMS ASVG-0.4-35k/4L-R(W) |
35 |
400 |
460*490*89 |
Forced Air Cooling |
AMS ASVG-0.4-50k/4L-R(W) |
50 |
400 |
500*510*190 |
Forced Air Cooling |
AMS ASVG-0.4-75k/4L-R(W) |
75 |
400 |
500*550*240 |
Forced Air Cooling |
AMS ASVG-0.4-100k/4L-R(W) |
100 |
400 |
500*550*240 |
ForcedAir Cooling |
Cabinet model |
||||
Models |
Compensation Capacity (kvar) |
System Voltage(V) |
Dimensions Width*Depth*Height(mm) |
Cooling System |
AMS ASVG-0.4-200k/4L-C |
200 |
400 |
1000*1000*2200 |
Forced Air Cooling |
AMS ASVG-0.4-250k/4L-C |
250 |
400 |
1000*1000*2200 |
Forced Air Cooling |
AMSASVG-0.4-300k/4L-C |
300 |
400 |
1000*1000*2200 |
Forced Air Cooling |
AMSASVG-0.4-400k/4L-C |
400 |
400 |
1000*1000*2200 |
Forced Air Cooling |
Note: -R(Rack)/ -W(Wall)/ -C(Cabinet)