All Categories
EN EN

AHF 400V SERIES

400V Active Harmonic Filter (AHF)

\n
Harmonic control, Reactive power compensation, Three-phase unbalance control
\n
Active harmonic filters (AHF) are the ultimate answer to power quality problems caused by waveform distortions, low power factor, voltage variations, voltage fluctuations and load unbalance for a wide range of segments and applications. They are a high performance, compact, flexible, modular and cost-effective type of active power filter (APF) which provide an instantaneous and effective response to power quality problems in low or high voltage electric power systems. They enable longer equipment lifetime, higher process reliability,improved power system capacity and stability, and reduced energy losses, complying with the most demanding power quality standards and grid codes.
\n
AHFs eliminate waveform distortions from the loads like harmonics, inter harmonics and notching,and harmonic voltages caused by harmonic currents, by injecting in real-time the distorted current of same magnitude but opposite in phase in the electric power system. In addition, AHFs can take care of several other power quality problems by combining different functions in a single device.
\n
AHF Working Principle:
\n
External CT detects the load current, DSP as CPU has advanced logic control arithmetic, could quickly track the instruction current, divides the load current into active power and reactive power by using the intelligent FFT, and calculates the harmonic content rapidly and accurately. Then it sends a PWM signal to the internal IGBT's driver board to control the IGBT on and off at 20KHZ frequency. Finally, it generates an opposite phase compensation current on inverter induction, at the same time CT also detects the output current and negative feedback goes to DSP. Then DSP proceeds to the next logical control to achieve a more accurate and stable system.
\n
\"AHF1.png\"
\n
\n
\n
\n
\n
AHF Technical Specifications
\n
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
TypeSeries 220VSeries 380V Series 500V Series 690V 
Norminal VoltageAC220V±20%AC380V±20%AC500V±20%AC690V±20%
Rated Frequency50Hz±5%
Compensating Current25A25A, 50A, 75A, 100A, 150A100A100A
NetworkL/N3P3W/3P4W
Response Time<10ms<40ms
Numbers in ParallelNo limitation
Harmonic Compensation Rate>92%
Harmonic Filtering 2~50th harmonics.
* The number of compensation can be selected.
* The range of single compensation can be adjusted
Machine Efficiency>97%
Switching Frequency32kHz16kHz12.8kHz
Communication MethodsTwo-channel RS485 communication interface 
(support GPRS/WIFI wireless communication)
Protection FunctionOverload protection, hardware over-current protection, over-voltage protection, power failure protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc
Altitude without Derating<2000m
Temperature-20℃ ~ 50℃
Humidity<90% RH
Pollution LevelBelow level Ⅲ
Noise<60dB<65dB
InstallationRack/Wall-mounted
Inlet WayBack entry (for Rack) / Top entry (for Wall-mounted)
Protection GradeIP20
\n
\n
\n
\"AHF2.png\"
\n
\n
\n
AHF Product Appearance
\n
1、Rack-mounted
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (A)System Voltage (V)Size (W1*D1*H1)Cooling Mode
AHF-0.22-25A/2L-R25220220*330*160Forced Air Cooling
AHF-0.4-25A/4L-R25400460*490*89Forced Air Cooling
AHF-0.4-50A/4L-R50400460*490*89Forced Air Cooling
AHF-0.4-75A-4L-R75400500*510*190Forced Air Cooling
AHF-0.4-100A/4L-R100400500*550*240Forced Air Cooling
AHF-0.4-150A/4L-R150400500*550*240Forced Air Cooling
AHF-0.5-100A/4L-R100500495*675*275Forced Air Cooling
AHF-0.69-100A/4L-R100690495*675*275Forced Air Cooling
\n
\n
\n
\"AHF3.png\"
\n
\n
\n
\n
\n
2、Wall-mounted
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (A)System Voltage (V)Size (W2*D2*H2)Cooling Mode
AHF-0.22-25A/2L-W25220220*160*330Forced Air Cooling
AHF-0.4-25A/4L-W25400460*89*490Forced Air Cooling
AHF-0.4-50A/4L-W50400460*89*490Forced Air Cooling
AHF-0.4-75A-4L-W75400500*190*510Forced Air Cooling
AHF-0.4-100A/4L-W100400500*240*550Forced Air Cooling
AHF-0.4-150A/4L-W150400500*240*550Forced Air Cooling
AHF-0.5-100A/4L-W100500495*275*675Forced Air Cooling
AHF-0.69-100A/4L-W100690495*275*675Forced Air Cooling
\n
\n
\"AHF4.jpg\"
\n
3、Full Cabinet Load
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ModelCompensation Capacity (A)System Voltage (V)Size (W3*D3*H3)Cooling Mode
AHF-0.4-100A/4L-C1004001000*1000*2200Forced Air Cooling
AHF-0.4-150A/4L-C1504001000*1000*2200Forced Air Cooling
AHF-0.4-200A/4L-C2004001000*1000*2200Forced Air Cooling
AHF-0.4-250A-4L-C2504001000*1000*2200Forced Air Cooling
AHF-0.4-300A/4L-C3004001000*1000*2200Forced Air Cooling
AHF-0.4-400A/4L-C4004001000*1000*2200Forced Air Cooling
AHF-0.5-300A/4L-C3005001000*1000*2200Forced Air Cooling
AHF-0.69-300A/4L-C3006901000*1000*2200Forced Air Cooling
\n
\n
\n
\"AHF5.png\"
\n
\n
\n
\n
\n
\n
\n
\n
\n
","info":"Active Harmonic Filter(AHF)\nHarmonic control, Reactive power compensation, Three-phase unbalance control\nActive harmonic filters (AHF) are the ultimate answer to power quality problems caused by waveform distortions, low power factor, voltage variations, voltage fluctuations and load unbalance for a wide range of segments and applications. They are a high performance, compact, flexible, modular and cost-effective type of active power filter (APF) which provide an instantaneous and effective response to power quality problems in low or high voltage electric power systems. They enable longer equipment lifetime, higher process reliability,improved power system capacity and stability, and reduced energy losses, complying with the most demanding power quality standards and grid codes.\nAHFs eliminate waveform distortions from the loads like harmonics, inter harmonics and notching,and harmonic voltages caused by harmonic currents, by injecting in real-time the distorted current of same magnitude but opposite in phase in the electric power system. In addition, AHFs can take care of several other power quality problems by combining different functions in a single device.\nAHF Working Principle:\nExternal CT detects the load current, DSP as CPU has advanced logic control arithmetic, could quickly track the instruction current, divides the load current into active power and reactive power by using the intelligent FFT, and calculates the harmonic content rapidly and accurately. Then it sends a PWM signal to the internal IGBT's driver board to control the IGBT on and off at 20KHZ frequency. Finally, it generates an opposite phase compensation current on inverter induction, at the same time CT also detects the output current and negative feedback goes to DSP. Then DSP proceeds to the next logical control to achieve a more accurate and stable system.\n\n\n\n\n\nAHF Technical Specifications\n\n\n \n\n\nType\nSeries 220V\nSeries 380V \nSeries 500V \nSeries 690V \n\n\nNorminal Voltage\nAC220V±20%\nAC380V±20%\nAC500V±20%\nAC690V±20%\n\n\nRated Frequency\n50Hz±5%\n\n\nCompensating Current\n25A\n25A, 50A, 75A, 100A, 150A\n100A\n100A\n\n\nNetwork\nL/N\n3P3W/3P4W\n\n\nResponse Time\n<10ms\n<40ms\n\n\nNumbers in Parallel\nNo limitation\n\n\nHarmonic Compensation Rate\n>92%\n\n\nHarmonic Filtering\n2~50th harmonics.* The number of compensation can be selected.* The range of single compensation can be adjusted\n\n\n\n\n\nMachine Efficiency\n>97%\n\n\nSwitching Frequency\n32kHz\n16kHz\n12.8kHz\n\n\nCommunication Methods\nTwo-channel RS485 communication interface \n\n\n\n\n\n(support GPRS/WIFI wireless communication)\n\n\nProtection Function\nOverload protection, hardware over-current protection, over-voltage protection, power failure protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc\n\n\nAltitude without Derating\n<2000m\n\n\nTemperature\n-20℃ ~ 50℃\n\n\nHumidity\n<90% RH\n\n\nPollution Level\nBelow level Ⅲ\n\n\nNoise\n<60dB\n<65dB\n\n\nInstallation\nRack/Wall-mounted\n\n\nInlet Way\nBack entry (for Rack) / Top entry (for Wall-mounted)\n\n\nProtection Grade\nIP20\n\n\n\n\n\n\n\n\nAHF Product Appearance\n1、Rack-mounted\n\n \n\n\nModel\nCompensation Capacity (A)\nSystem Voltage (V)\nSize (W1*D1*H1)\nCooling Mode\n\n\n\n\nAHF-0.22-25A/2L-R\n25\n220\n220*330*160\nForced Air Cooling\n\n\nAHF-0.4-25A/4L-R\n25\n400\n460*490*89\nForced Air Cooling\n\n\nAHF-0.4-50A/4L-R\n50\n400\n460*490*89\nForced Air Cooling\n\n\nAHF-0.4-75A-4L-R\n75\n400\n500*510*190\nForced Air Cooling\n\n\nAHF-0.4-100A/4L-R\n100\n400\n500*550*240\nForced Air Cooling\n\n\nAHF-0.4-150A/4L-R\n150\n400\n500*550*240\nForced Air Cooling\n\n\nAHF-0.5-100A/4L-R\n100\n500\n495*675*275\nForced Air Cooling\n\n\nAHF-0.69-100A/4L-R\n100\n690\n495*675*275\nForced Air Cooling\n\n\n\n\n\n\n\n\n\n\n2、Wall-mounted\n\n\n\n\nModel\nCompensation Capacity (A)\nSystem Voltage (V)\nSize (W2*D2*H2)\nCooling Mode\n\n\n\n\nAHF-0.22-25A/2L-W\n25\n220\n220*160*330\nForced Air Cooling\n\n\nAHF-0.4-25A/4L-W\n25\n400\n460*89*490\nForced Air Cooling\n\n\nAHF-0.4-50A/4L-W\n50\n400\n460*89*490\nForced Air Cooling\n\n\nAHF-0.4-75A-4L-W\n75\n400\n500*190*510\nForced Air Cooling\n\n\nAHF-0.4-100A/4L-W\n100\n400\n500*240*550\nForced Air Cooling\n\n\nAHF-0.4-150A/4L-W\n150\n400\n500*240*550\nForced Air Cooling\n\n\nAHF-0.5-100A/4L-W\n100\n500\n495*275*675\nForced Air Cooling\n\n\nAHF-0.69-100A/4L-W\n100\n690\n495*275*675\nForced Air Cooling\n\n\n\n\n\n3、Full Cabinet Load\n\n\n\n\nModel\nCompensation Capacity (A)\nSystem Voltage (V)\nSize (W3*D3*H3)\nCooling Mode\n\n\n\n\nAHF-0.4-100A/4L-C\n100\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.4-150A/4L-C\n150\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.4-200A/4L-C\n200\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.4-250A-4L-C\n250\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.4-300A/4L-C\n300\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.4-400A/4L-C\n400\n400\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.5-300A/4L-C\n300\n500\n1000*1000*2200\nForced Air Cooling\n\n\nAHF-0.69-300A/4L-C\n300\n690\n1000*1000*2200\nForced Air Cooling\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n","desc":"Active Harmonic Filter(AHF)\nHarmonic control, Reactive power compensation, Three-phase unbalance control\nActive harmonic filters (AHF) are the ultimate answer to power quality problems caused by waveform distortions, low power factor, voltage variati...","date":"2024-10-23","visits":0,"color":"","category":"AHF 400V Series","sname":"","slink":"https://www.ampersure.com/75a","tag":"","down":"
","downname":"","downurl":"","prev":null,"next":null,"count":1,"specs":[],"skus":[],"product_summary":"","product_image_video":"","brand_manufacturer":"","product_code_spu":"","extension_title":"","extension_content":[{"extension_title":"","extension_content":""}],"product_price":"0.00","need_show_price":0}
  • Overview
  • Related Products
Active Harmonic Filter(AHF)
Harmonic control, Reactive power compensation, Three-phase unbalance control
Active harmonic filters (AHF) are the ultimate answer to power quality problems caused by waveform distortions, low power factor, voltage variations, voltage fluctuations and load unbalance for a wide range of segments and applications. They are a high performance, compact, flexible, modular and cost-effective type of active power filter (APF) which provide an instantaneous and effective response to power quality problems in low or high voltage electric power systems. They enable longer equipment lifetime, higher process reliability,improved power system capacity and stability, and reduced energy losses, complying with the most demanding power quality standards and grid codes.
AHFs eliminate waveform distortions from the loads like harmonics, inter harmonics and notching,and harmonic voltages caused by harmonic currents, by injecting in real-time the distorted current of same magnitude but opposite in phase in the electric power system. In addition, AHFs can take care of several other power quality problems by combining different functions in a single device.
AHF Working Principle:
External CT detects the load current, DSP as CPU has advanced logic control arithmetic, could quickly track the instruction current, divides the load current into active power and reactive power by using the intelligent FFT, and calculates the harmonic content rapidly and accurately. Then it sends a PWM signal to the internal IGBT's driver board to control the IGBT on and off at 20KHZ frequency. Finally, it generates an opposite phase compensation current on inverter induction, at the same time CT also detects the output current and negative feedback goes to DSP. Then DSP proceeds to the next logical control to achieve a more accurate and stable system.
AHF1.png
AHF Technical Specifications
Type Series 220V Series 380V  Series 500V  Series 690V 
Norminal Voltage AC220V±20% AC380V±20% AC500V±20% AC690V±20%
Rated Frequency 50Hz±5%
Compensating Current 25A 25A, 50A, 75A, 100A, 150A 100A 100A
Network L/N 3P3W/3P4W
Response Time <10ms <40ms
Numbers in Parallel No limitation
Harmonic Compensation Rate >92%
Harmonic Filtering 2~50th harmonics.
* The number of compensation can be selected.
* The range of single compensation can be adjusted
Machine Efficiency >97%
Switching Frequency 32kHz 16kHz 12.8kHz
Communication Methods Two-channel RS485 communication interface 
(support GPRS/WIFI wireless communication)
Protection Function Overload protection, hardware over-current protection, over-voltage protection, power failure protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc
Altitude without Derating <2000m
Temperature -20℃ ~ 50℃
Humidity <90% RH
Pollution Level Below level Ⅲ
Noise <60dB <65dB
Installation Rack/Wall-mounted
Inlet Way Back entry (for Rack) / Top entry (for Wall-mounted)
Protection Grade IP20
AHF2.png
AHF Product Appearance
1、Rack-mounted
Model Compensation Capacity (A) System Voltage (V) Size (W1*D1*H1) Cooling Mode
AHF-0.22-25A/2L-R 25 220 220*330*160 Forced Air Cooling
AHF-0.4-25A/4L-R 25 400 460*490*89 Forced Air Cooling
AHF-0.4-50A/4L-R 50 400 460*490*89 Forced Air Cooling
AHF-0.4-75A-4L-R 75 400 500*510*190 Forced Air Cooling
AHF-0.4-100A/4L-R 100 400 500*550*240 Forced Air Cooling
AHF-0.4-150A/4L-R 150 400 500*550*240 Forced Air Cooling
AHF-0.5-100A/4L-R 100 500 495*675*275 Forced Air Cooling
AHF-0.69-100A/4L-R 100 690 495*675*275 Forced Air Cooling
AHF3.png
2、Wall-mounted
Model Compensation Capacity (A) System Voltage (V) Size (W2*D2*H2) Cooling Mode
AHF-0.22-25A/2L-W 25 220 220*160*330 Forced Air Cooling
AHF-0.4-25A/4L-W 25 400 460*89*490 Forced Air Cooling
AHF-0.4-50A/4L-W 50 400 460*89*490 Forced Air Cooling
AHF-0.4-75A-4L-W 75 400 500*190*510 Forced Air Cooling
AHF-0.4-100A/4L-W 100 400 500*240*550 Forced Air Cooling
AHF-0.4-150A/4L-W 150 400 500*240*550 Forced Air Cooling
AHF-0.5-100A/4L-W 100 500 495*275*675 Forced Air Cooling
AHF-0.69-100A/4L-W 100 690 495*275*675 Forced Air Cooling
AHF4.jpg
3、Full Cabinet Load
Model Compensation Capacity (A) System Voltage (V) Size (W3*D3*H3) Cooling Mode
AHF-0.4-100A/4L-C 100 400 1000*1000*2200 Forced Air Cooling
AHF-0.4-150A/4L-C 150 400 1000*1000*2200 Forced Air Cooling
AHF-0.4-200A/4L-C 200 400 1000*1000*2200 Forced Air Cooling
AHF-0.4-250A-4L-C 250 400 1000*1000*2200 Forced Air Cooling
AHF-0.4-300A/4L-C 300 400 1000*1000*2200 Forced Air Cooling
AHF-0.4-400A/4L-C 400 400 1000*1000*2200 Forced Air Cooling
AHF-0.5-300A/4L-C 300 500 1000*1000*2200 Forced Air Cooling
AHF-0.69-300A/4L-C 300 690 1000*1000*2200 Forced Air Cooling
AHF5.png

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000